• DS-TESU non-standard signal isolators DS-TESU non-standard signal isolators

DS-TESU non-standard signal isolators

Item No: DYT12168185

Quick Overview

Get best and cheap DS-TESU non-standard signal isolators from circuitsell.com with Fast Delievry and Free Worldwide Shipping...

Availability: In stock

$200.00

$69.99

* Required Fields

Order within and your item will ship out today

Details

DS-TESU non-standard signal isolators

· Isolation conversion of various non-standard signals. For example, 0~10V, -10~+10V, 0~5mV, 0~10mV, 0~20mA, 0~10mA. Independent DC power supply is required, and power-input-output isolation.
· DS-TESU DC signal isolator realizes the conversion between various non-standard signals through simple switching of internal circuits, but it needs to follow the definitions and specifications in the following “Model and Selection Instructions” column when ordering. Non-standard models in the following model ranges can also be ordered by custom non-standard models, but both parties need to confirm.
· This product requires a separate DC power supply. Voltage-type magnetic isolation between power supply-input-output.
· Small plug-in structure, universal base type terminal, standardized wiring and easy installation.

 

Model / selection table:

     Option

    Model and code

     Description

    Basic model

    DS-TESU

     DC Signal Isolator

    Channel form

         11

     1 in 1 out

         12

     1 in 2 out

Input signal / Output signal

        -A1

     0~20mA input / 0~5V output

        -A2

     0~20mA input / 0~5V output

        -A3

     0~20mA input / 0~10V output

        -A4

     0~20mA input / 1~5V output

        -A5

     0~20mA input / -10~10V output

        -B1

     4~20mA input / 0~20mA output

        -B2

     4~20mA input/ 0~5V output

        -B3

     4~20mA input / 0~10V output

        -B4

     4~20mA input / 1~5V output

        -B5

     4~20mA input / -10~10V output

        -C1

     4~20mA input / 0~10mA output

        -C2

     0~10mA input / 4~20mA output

        -D1

     0~5V  input / 4~20mA output

        -D2

     0~5V  input / 0~20mA output

        -D3

     0~5V  input / 0~5V output

        -D4

     0~5V  input / 0~10V output

        -D5

     0~5V  input / 1~5V output

        -D6

     0~5V  input / -10~10V output

        -E1

     0~10V  input / 4~20mA output

        -E2

     0~10V  input / 0~20mA output

        -E3

     0~10V  input / 0~5V output

        -E4

     0~10V  input / 0~10V output

        -E5

     0~10V  input / 1~5V output

        -E6

     0~10V  input / -10~10V output

        -F1

     1~5V   input / 4~20mA output

        -F2

     1~5V  input / 0~20mA output

        -F3

     1~5V  input / 0~5V output

        -F4

     1~5V  input / 0~10V output

        -F5

     1~5V  input / 1~5V output

        -F6

     1~5V  input / -01~10V output

        -G1

     -01~10V  input / 4~20mA output

        -G2

     -01~10V  input / 0~20mA output

        -G3

     -01~10V  input / 0~5V output

        -G4

     -01~10V  input / 0~10V output

        -G5

     -01~10V  input / 1~5V output

        -G6

     -01~10V  input / -10~10V output

        -H1

     0~5mV  input / 4~20mA output

        -H2

     0~10mV  input / 4~20mA output

        -H3

     0~100mV  input / 4~20mA output

        -T1

     indexing range  input / 4~20mA output

        -ZZ

     Special designated order

     Power supply Voltage

       -V1

     Power supply (terminal) 2032VDC

       -V2

     Power supply (rail) 2032VDC (Need to be equipped with dedicated power supply DIN rail)

     Service code

    -QC9A

     Product Service Code

   Selection example 
  Example 1: DS-TESU11-E4-V1-QC9A ...... (1 input and 1 output, signal isolator, 0~10V input, 0~10V output, terminal power supply 20~32VDC) 
   Example 2: DS-TESU12-B3-V1-QC9A ...... (1 input and 2 output, signal isolator, 4~20mA input, 0~10V output, terminal power supply 20~32VDC) 
   Example 3: DS-TESU12-ZZ-V1-QC9A ...... (1 input and 2 output, signal isolator, 0~20mA input, 1st output 0~20mA, 2nd output 0~10V, terminal power supply 20~32VDC 
  Indication 
   1. Input 4~20mA is optional with power distribution, input by 1, 2 terminals. See the wiring diagram. 
   2. When 4~20mA current output, if the output loop power supply function is required, order can be specified when ordering. 
   Optional accessories 
   Dedicated power supply DIN rail: PSDR-3000 series

Technical data:

Size:

Width

    14.5mm

     Height

    102.6mm

     Height

    124mm

     Housing Material / Color

    PC (Polycarbonate) + PPT Material / Black Gray 

Protection level  

    IP20

 

Environmental conditions:

    Ambient temperature

    -20~60℃

   Ambient temperature (storage or operation)

    -40~80℃

  Ambient humidity (operation)

    5~95RH (no condensation)

 

Input:

   Input signal

    4~20mA ;  0~20mA ;  0~10mA ;
    1~5V ; 0~5V ; 0~10V ; -10~10V ;
    0~5mV ; 0~10mV ; 0~100mV ;
    Or other designation

   Input impedance

    When inputting current,≥25Ω
    200KΩ when voltage is input

 

Output:

   Output signal

    4~20mA; 0~20mA; 0~10mA;
    1~5V; 0~5V; 0~10V; -10~10V
    Or other designation

   Output load

    Current output load 0~300Ω; voltage output load ≥100KΩ

   Output ripple

    <10mV p-p

 

Power supply:

     Rated supply voltage

    24VDC

     Power supply voltage range

    20~32VDC

Maximum current consumption

    <35mA (1 in 1 out); <70mA (1 in 2 out)

 

General parameters:

   Standard accuracy

    Typical values±0.1%FS

Temperature drift

    ±1μA/10℃

Power-on or storage time drift

    ±2μA (180days)

Load change effect

    ±2μA

Response time

    <10ms

Power-on stabilization time

    <1s

Electrical isolation

    Input-output-power supply: 2500V AC RMS / 1 minute

Protection parameters

    · Power-on shock protection, power-on slow start >20ms
    · Reverse power supply protection, reverse voltage -30V
    · Output protection, output clamp current 25mA (typical)
    · Port misconnection and surge protection:
       A. The power-input-output between the two ports of the self-loop can withstand the external loop voltage <±24V.
       B. Input-output-power supply can withstand 2500V RMS/1 minute without damage.
       C. The short circuit or open circuit formed by the misconnection of the terminal is not damaged.

Electromagnetic compatibility (EMC)

    In accordance with IEC 61326-1 (GB/T 18268), IEC 61326-3-1

LED backlight indication

    Power up, the product model on the panel is clearly visible through the LED backlight perspective, white.

Field device suitable for connection

    DC signal source

Mounting method

    Horizontal or vertical mounting, can be mounted on standard 35mm DIN rail (or dedicated busbar backplane powered DIN rail)

 

Wiring parameters:

   Rigid conductor cross section (min/max)

    0.5mm²/2.5mm²

   Flexible wire cross section (min/max)

    0.5mm²/2.5mm²

   Minimum wire cross section (AWG)

    24

   Maximum wire cross section (AWG)

    14

   Stripping length

    7mm

   Connection type

    M3 screw fastening connection

   crew torque

    up to 0.6Nm

 

Certification/standards:

    CE certification

    Meet CE standards

 

Product diagram / terminal wiring diagram:

 

           

Product Image Details

DS-TESU non-standard signal isolators 1

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

Only registered users can write reviews. Please Log In or Register

Product Questions

  • Submit your question to our community.


Our customers love us

  • High Quality With Global Standards.
  • Convenient and friendly customer service.
  • Fast and safe shipping around the globe.
  • Free Shipping Worldwide - Each Order, and no any tax!