• DS-TP11BJ Universal signal alarm setter DS-TP11BJ Universal signal alarm setter

DS-TP11BJ Universal signal alarm setter

Item No: DYT12168155

Quick Overview

Get best and cheap DS-TP11BJ Universal signal alarm setter from circuitsell.com with Fast Delievry and Free Worldwide Shipping...

Availability: In stock

$200.00

$69.99

* Required Fields

Order within and your item will ship out today

Details

DS-TP11BJ Universal signal alarm setter

·Universal purpose signal (RTD/TC/mV/mA), configurable settings. LCD display (optional) or LED backlight indication. Analog signal output + relay contact alarm output.
· DS-TP11BJ alarm setter is based on the general signal isolator to add a set of relay contacts for power distribution, current, thermal resistance, thermocouple, millivolt signal, line resistance and other signal alarm output. It is a multi-function instrument that integrates signal alarm, signal transmission and isolation functions.
· Switch power distribution, current, RTD, thermocouple, and millivolt signal input according to different wiring methods. The input signal type or range can be configured via software.
· Relay contact alarm output, contact capacity 12VDC, 1A.
· This product requires a separate DC power supply. Voltage-type magnetic isolation between power supply-input-output.

 

Model / selection table:

Option

    Model and code

     Description

Basic model

    DS-TP11BJ

     Universal signal alarm setter

Input signal

        -U

     Universal signal(RTD ,TC , mV , mA

Output signal

         A

     4~20mA

         B

     0~20mA

         Z

     Special order

Power supply voltage

       -V1

     Power supply (terminal) 2032VDC

       -V2

     Power supply (rail) 2032VDC (Need to be equipped with dedicated power supply DIN rail)     

Service code

      -QC9A

     Product Service Code

   Selection example

   Example 1: DS-TPX11BJ-UA-V1-QC9A
...... (General signal alarm setter with display, 4~20mA output + one set of relay contact alarm output, terminal power supply 20~32VDC)
Example 2: DS-TP11BJ-UA-V2-QC9A
...... (General signal alarm setter, 4~20mA output + one set of relay contact alarm output, rail supply 20~32VDC)   

Indication  
   1. Please indicate the signal type and range when ordering. Otherwise, it will be shipped according to the default setting: with power distribution, input signal 4~20mA, output signal 4~20mA.
     2. If you select a rail-powered product, please order a dedicated DIN rail.

Optional accessories 
      · Configuration software: CRFW-2000, CRFA-1904
     · Calibration interface: CR-2206, FAIF-1904
     · Dedicated power supply DIN rail: PSDR-3000 series

Technical data:

Size:

Width

     14.5mm

     Height

     102.6mm

     Height

     124mm

     Housing Material / Color

     PC (Polycarbonate) + PPT Material / Black Gray 

Protection level  

     IP20

 

Environmental conditions:

    Ambient temperature

     -20~60℃

   Ambient temperature (storage or operation)

     -40~80℃

    Ambient humidity (operation)

     5~95RH (no condensation)

 

Input:

    Available sensor types(RTD

     Pt100Cu50 and other thermal resistance

    Available sensor types(TC

     KESB and other thermocouples

   Temperature measurement range

     Depends on sensor type

   Millivolt signal

     0~100mV

    Current signal

   

    0/4~20mA

   Distribution voltage to the transmitter

     ≥17V (at20mA)

 

Output:

   Current output signal

     4~20mA ;  0~20mA

Maximum current output signal

     22mA(±1mA)

   Current output load

     Adaptive load 0~300Ω

   Output ripple

     <10mV p-p

   Alarm output

     relay contact

   Contact capacity

     12V1A

   Load Type

     Resistive Load

 

Power supply:

Rated supply voltage

     24VDC

     Power supply voltage range

     20~32VDC

    Maximum current consumption

     <60mA  

 

General parameters:

    Standard accuracy

    Typical values±0.1%FS

     Zero migration range

    -10~100mVor0~385Ω

    Range migration range

    3.8~100mVor12.8~400Ω

   Output resolution

    <3.8~100mVor12.8Ω~400Ωrange, 1μA

Thermocouple input, cold junction compensation error

    ±0.5~1°C (compensation range -15~+75°C)

   Wire resistance effect

    Thermal resistance three-wire input (≤10Ω/line), <±0.005 %/Ω

    Load change impact

    ±2μA

   Temperature drift

· -10~35 mV range: 0.0005% or 0.6μV (whichever is larger)
· -10~75 mV range: 0.0005% or 1.2μV (take the larger one)
· 10~400Ω range: 0.0015% or 4mΩ (whichever is larger)

Power-on or storage time drift

    ±2μA (180days)

Response time

    <10ms

Power-on stabilization time

    <1s

Maximum withstand voltage

    Input-output-power supply: 2500V AC RMS / 1 minute

Protection parameters

· Power-on shock protection, power-on slow start >20ms
· Distribution protection, distribution output clamp current 28mA (±4mA)
· Reverse power supply protection, reverse voltage -30V
· Output protection, output clamp current 22mA (typical)
· Port misconnection and surge protection:
A. The power-input-output between the two ports of the self-loop can withstand the external loop voltage <±24V.
B. Input-output-power supply can withstand 2500V RMS/1 minute without damage.
C. The short circuit or open circuit formed by the misconnection of the terminal is not damaged.

Electromagnetic compatibility (EMC)

    In accordance with IEC 61326-1 (GB/T 18268), IEC 61326-3-1

LCD display or LED backlight indication

· LCD display: input value and output value
· LED backlight indication: Power on, the product model on the panel is clearly visible through the LED backlight perspective, white.

Field device suitable for connection

   Thermal resistance or thermocouple temperature sensor, millivolt signal, transmitter or current source signal

Mounting method

    Horizontal or vertical mounting, can be snapped onto standard 35mm DIN rail (or dedicated busbar backplane)
Power supply on DIN rail)

 

Wiring parameters:

   Rigid conductor cross section (min/max)

    0.5mm²/2.5mm²

   Flexible wire cross section (min/max)

    0.5mm²/2.5mm²

   Minimum wire cross section (AWG)

    24

   Maximum wire cross section (AWG)

    14

   Stripping length

    7mm

   Connection type

    M3 screw fastening connection

   crew torque

    up to 0.6Nm

 

Certification/standards:

    CE certification

    Meet CE standards

 

Product diagram / terminal wiring diagram:

 

           

Product Image Details

DS-TP11BJ Universal signal alarm setter 1

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

Only registered users can write reviews. Please Log In or Register

Product Questions

  • Submit your question to our community.


Our customers love us

  • High Quality With Global Standards.
  • Convenient and friendly customer service.
  • Fast and safe shipping around the globe.
  • Free Shipping Worldwide - Each Order, and no any tax!