• TC-TP11BJ Universal signal alarm setter TC-TP11BJ Universal signal alarm setter

TC-TP11BJ Universal signal alarm setter

Item No: DYT12168199

Quick Overview

Get best and cheap TC-TP11BJ Universal signal alarm setter from circuitsell.com with Fast Delievry and Free Worldwide Shipping...

Availability: In stock

$200.00

$69.99

* Required Fields

Order within and your item will ship out today

Details

TC-TP11BJ Universal signal alarm setter

· General purpose signal (RTD/TC/mV/mA), configurable settings. LCD display (optional) or LED backlight indication. Analog signal output + relay contact alarm output.
· The TC-TP11BJ Alarm Setter adds a set (or two sets) of relay contacts to the general purpose signal isolator.
Alarm output for power distribution, current, thermal resistance, thermocouple, millivolt signal, and slip line resistance. Is set alarm, signal separation
A multi-function meter that is integrated into the function.
· Switch power distribution, current, RTD, thermocouple, and millivolt signal input according to different wiring methods. Input signal type
Or the range can be configured via software.
· Alarm output relay contact (normally open), contact capacity 12VDC, 1A.
· This product requires a separate DC power supply. Voltage-type magnetic isolation between power supply-input-output.

 

Model / selection table:

   Option

     Model and code

    Description

   Basic model

    TC-TP11BJ

    Universal signal alarm setter (set of alarm outputs)

    TC-TPX11BJ

    With display, universal signal alarm setter (a set of alarm outputs)

    TC-TP11BJ-BJ

    General signal alarm setter (two sets of alarm output)

    TC-TPX11BJ-BJ

    With display, universal signal alarm setter (two sets of alarm output)

   Input signal

        -U

    General purpose signal (RTD , TC , mV, mA)

   Output signal

         A

     4~20mA

         B

     0~20mA

         Z

     Special order

   Power supply voltage

       -V1

     Power supply (terminal) 2032VDC

       -V2

     Power supply (rail) 2032VDC (special power supply DIN rail required)

   Service Code

    -QC9A

     Product Service Code

   Selection example 
   Example 1: TC-TPX11BJ-BJ-UA-V1-QC9A ...... (general signal alarm setter, two-way alarm, with display, 4~20mA output, terminal power supply 20~32VDC) 
   Example 2: TC-TP11BJ-UA-V2-QC9A ...... (general signal alarm setter, one way alarm, 4~20mA output, rail supply 20~32VDC)
Indicate 
   Indication 
   1. Please indicate the signal type and range when ordering. Otherwise, it will be shipped according to the default setting: with power distribution, input signal 4~20mA, output signal 4~20mA. 
   2. If you select a rail-powered product, please order a dedicated DIN rail. 
   Optional accessories 
   · Configuration software: CRFW-2000, CRFA-1904 
   · Calibration interface: CR-2206, FAIF-1904 
   · Dedicated power supply DIN rail: PSDR-3000 series

 

Technical data:

Size:

Width

     12.7mm

     Height

     119.3mm

     Height

115.7mm

     Housing Material / Color

PC (Polycarbonate) + PPT Material / Black Gray 

Protection level  

IP20

 

Environmental conditions:

    Ambient temperature

    -20~60℃

   Ambient temperature (storage or operation)

    -40~80℃

Ambient humidity (operation)

    5~95RH (no condensation)

 

Input:

   Available sensor types(RTD

    Pt100Cu50 and other thermal resistance

   Available sensor types(TC

    KESB and other thermocouples

   Temperature measurement range

    Depends on sensor type

   Millivolt signal

    0~100mV

   Current signal

    0/4~20mA

   Distribution voltage to the transmitter

    ≥17V (at20mA)

 

Output:

   Current output signal

    4~20mA ;  0~20mA

Maximum current output signal

    22mA(±1mA)

   Current Output Load

    Adaptive Load 0~300Ω (factory default)

   Output ripple

    <10mV p-p

   Alarm output

    Relay contact

   Contact capacity

    12V1A

   Load Type

    Resistive Load

 

Power supply:

Rated supply voltage

    24VDC

Power supply voltage range

    20~32VDC

Maximum current consumption

    60mA  

 

General parameters:

   Standard accuracy

    Typical values±0.1%FS

   Zero migration range

    -10~100mVor0~385Ω

   Range migration range

    3.8~100mVor12.8~400Ω

   Output resolution

    3.8~100mVor12.8Ω~400Ωrange, 1μA

   Load change impact

    ±2μA 

   Thermocouple input, cold junction compensation error

    ±0.5~1°C (compensation range -15~+75°C)

   Thermal resistance input, wire resistance effect

    Thermal resistance three-wire input (≤10Ω/line), <±0.005 %/Ω

   Temperature drift

· -10~35mV range: 0.0005% or 0.6μV (whichever is larger)
· -10~75mV range: 0.0005% or 1.2μV (take the larger one)
· 10~400Ω range: 0.0015% or 4mΩ (whichever is larger)

   Power-on or storage time drift

    ±2μA (180days)

   Response time

    <10ms

   Power-on stabilization time

    <1s

   Maximum withstand voltage

    Input-output-power supply: 2500V AC RMS / 1 minute

   Protection parameters

· Power-on shock protection, power-on slow start >20ms
· Distribution protection, distribution output clamp current 28mA (±4mA)
· Reverse power supply protection, reverse voltage -30V
· Output protection, output clamp current 22mA (typical)
· Port misconnection and surge protection:
A. The power-input-output between the two ports of the self-loop can withstand the external loop voltage <±24V.
B. Input-output-power supply can withstand 2500V RMS/1 minute without damage.
C. The short circuit or open circuit formed by the misconnection of the terminal is not damaged.

   Electromagnetic compatibility (EMC)

    In accordance with IEC 61326-1 (GB/T 18268), IEC 61326-3-1

   LCD display or LED backlight indication

· LCD display: input value and output value
· LED backlight indication: Power on, the product model on the panel is clearly visible through the LED backlight perspective, white.

   Field device suitable for connection

    Thermal resistance or thermocouple temperature sensor, millivolt signal, transmitter or current source signal

   Mounting method

    Horizontal or vertical mounting, can be snapped onto standard 35mm DIN rail (or dedicated busbar backplane)
Power supply on DIN rail)

 

Wiring parameters:

   Rigid conductor cross section (min/max)

    0.5mm²/2.5mm²

   Flexible wire cross section (min/max)

    0.5mm²/2.5mm²

   Minimum wire cross section (AWG)

    24

   Maximum wire cross section (AWG)

    14

   Stripping length

    7mm

   Connection type

    M3 screw fastening connection

   Crew torque

    up to 0.6Nm

 

Certification/standards:

   CE certification

    Meet CE standards

Product diagram / terminal wiring diagram:

 

           

Product Image Details

TC-TP11BJ Universal signal alarm setter 1

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

Only registered users can write reviews. Please Log In or Register

Product Questions

  • Submit your question to our community.


Our customers love us

  • High Quality With Global Standards.
  • Convenient and friendly customer service.
  • Fast and safe shipping around the globe.
  • Free Shipping Worldwide - Each Order, and no any tax!