You have no items to compare.
Hi, Dear! Welcome to our online store...
XS-TP11BJ Universal signal alarm setter
· General purpose signal (RTD/TC/mV/mA), configurable settings. Analog signal output + relay contact alarm output.
· The XS-TP11BJ Alarm Setter adds a set of relay contacts to the alarm output of power distribution, current, thermal resistance, thermocouple, millivolt signal, and slip line resistance based on the general signal isolator. It is a multi-function instrument that integrates signal alarm, signal transmission and isolation functions.
· Switch power distribution, current, RTD, thermocouple, and millivolt signal input according to different wiring methods. The input signal type or range can be configured via software.
· Relay contact alarm output, contact capacity 12VDC, 1A.
· This product requires a separate DC power supply. Voltage-type magnetic isolation between power supply-input-output.
Model / selection table:
Option |
Model and code |
Description |
Basic model |
XS-TP11BJ |
Universal Signal Alarm Setter |
Input signal |
-U |
General purpose signal (RTD,TC, mV, mA) |
Output signal |
A |
4~20mA |
B |
0~20mA |
|
Z |
Special order |
|
Power supply voltage |
-V1 |
Power supply (terminal) 20~32VDC |
-V2 |
Power supply (rail) 20~32VDC (special power supply DIN rail required) |
|
Service Code |
-QC9A |
Product Service Code |
Selection example |
Technical data:
Size:
Width |
14.5mm |
Height |
102.6mm |
Height |
100mm |
Housing Material / Color |
PC (Polycarbonate) + PPT Material / Black Gray |
Protection level |
IP20 |
Environmental conditions:
Ambient temperature |
-20~+60℃ |
Ambient temperature (storage or operation) |
-40~+80℃ |
Ambient humidity (operation) |
5~95%RH (no condensation) |
Input:
Available sensor types(RTD) |
Pt100,Cu50 and other thermal resistance |
Available sensor types(TC) |
K,E,S,B and other thermocouples |
Temperature measurement range |
Depends on sensor type |
Millivolt signal |
0~100mV |
Current signal |
0/4~20mA |
Distribution voltage to the transmitter |
≥17V (at20mA) |
Output:
Current output signal |
4~20mA ; 0~20mA |
Maximum current output signal |
22mA(±1mA) |
Current Output Load |
Adaptive Load 0~300Ω (factory default) |
Output ripple |
<10mV p-p |
Alarm output |
Relay contact |
Contact capacity |
12V,1A |
Load Type |
Resistive Load |
Power supply:
Rated supply voltage |
24VDC |
Power supply voltage range |
20~32VDC |
Maximum current consumption |
<60mA |
General parameters:
Standard accuracy |
Typical values±0.1%FS |
Zero migration range |
-10~100mV or 0~385Ω |
Range migration range |
3.8~100mV or 12.8~400Ω |
Output resolution |
<3.8~100mV or 12.8Ω~400Ωrange, 1μA |
Load change effect |
±2μA |
Wire resistance effect |
Thermal resistance three-wire input(≤10Ω/line), <±0.005 %/Ω |
Thermocouple input cold junction compensation error |
±0.5~1℃ (compensation range -15~+75℃) |
Temperature drift |
· -10~35mV range: 0.0005% or 0.6μV (whichever is larger) |
Power-on or storage time drift |
±2μA (180days) |
Response time |
<10ms |
Power-on stabilization time |
<1s |
Maximum withstand voltage |
Input-output-power supply: 2500V AC RMS / 1 minute |
Protection parameters |
· Power-on shock protection, power-on slow start >20ms |
Electromagnetic compatibility (EMC) |
In accordance with IEC 61326-1 (GB/T 18268), IEC 61326-3-1 |
LED indication |
Green LED (power indication) |
Field device suitable for connection |
Thermal resistance or thermocouple temperature sensor, millivolt signal, transmitter or current source signal |
Mounting method |
Horizontal or vertical mounting, can be mounted on standard 35mm DIN rail (or dedicated busbar backplane powered DIN rail) |
Wiring parameters:
Rigid conductor cross section (min/max) |
0.5mm²/2.5mm² |
Flexible wire cross section (min/max) |
0.5mm²/2.5mm² |
Minimum wire cross section (AWG) |
24 |
Maximum wire cross section (AWG) |
14 |
Stripping length |
7mm |
Connection type |
M3 screw fastening connection |
Crew torque |
up to 0.6Nm |
Certification/standards:
CE certification |
Meet CE standards |
Product diagram / terminal wiring diagram: