• XSA-PI /PD/ II power distribution or current input barrier XSA-PI /PD/ II power distribution or current input barrier

XSA-PI /PD/ II power distribution or current input barrier

Item No: DYT12168152

Quick Overview

Get best and cheap XSA-PI /PD/ II power distribution or current input barrier from circuitsell.com with Fast Delievry and Free Worldwide Shipping...

Availability: In stock

$200.00

$69.99

* Required Fields

Order within and your item will ship out today

Details

XSA-PI (PD, II) power distribution or current input barrier

·  1 in 1 out, 1 in 2 out, 2 in 2 out. 0/4~20mA intrinsically safe input. Distribution voltage ≥16V (at 20mA). 0/4~20mA output. HART passed. Terminal supply or DIN rail power supply is available.

·   The XSA-PI (PD, II) is designed to be connected to a transmitter or current source in a hazardous area on site, to provide electrical distribution to the field transmitter, and to accept current signal input from the transmitter. Current source signal input can also be accepted separately. After isolation, interference suppression, etc., output standard current signals to the safety zone control system or other instruments.

·  Output signal 4~20mA or 0~20mA.

·  This product requires a separate DC power supply. Voltage-type magnetic isolation between power supply-input-output.

Model /Selection Table:

     Option

    Model and code

     Description

     Basic model

    XSA-PI

     Power distribution or current input barrier

    XSA-PD

     Dual channel, power distribution input barrier (only adapts to channel type 2 in 2 out options)

    XSA-II

     Dual channel, current input barrier (only adapts to channel type 2 in 2 out options)

     Special function

        H

     HART pass (only for the basic model XSA-PI option)

        F

     Input line fault alarm

   

     Default, no special features

     Channel form

        11

     1 in 1 out

        12

     1 in 2 out

        22

     2 in 2 out (adapt to the basic model XSA-PD or XSA-II option)

     Input signal

        -A

     4~20mA or 0~20mA

     Output signal

        A

     4~20mA or 0~20mA (1 to 1 corresponds to the input signal)

        Z

     Special order

     Power supply voltage

       -V1

     Power supply (terminal)2032VDC

       -V2

     Power supply (rail) 20~32VDC (special power supply DIN rail required)

     Service Code

    -QC9A

     Product Service Code

   Selection example 
   Example 1: XSA-PIH11-AA-V1-QC9A...... (1 in 1 out, power distribution or current input safety barrier, HART pass, current signal 0/4~20mA, terminal power supply 20~32VDC) 

Example 2: XSA-PIF12-AA-V1-QC9A...... (1 in 2 out, power distribution or current input safety barrier, with line fault alarm, current signal 0/4~20mA, terminal power supply 20~32VDC)

Example 3: XSA-PD22-AA-V1-QC9A ...... (2 in 2 out, power distribution input safety barrier, current signal 0/4~20mA, terminal power supply 20~32VDC
   Example 4: XSA-II22-AA-V2-QC9A ...... (2 in 2 out, current input safety barrier, current signal 0/4~20mA, rail supply 20~32VDC)
  Optional accessories 

Dedicated power supply DIN rail: PSDR-3000 series

 

Technical data:

Size:

    Width

    14.5mm

    Height

    102.6mm

    Depth

    100mm

    Housing Material / Color

    PC(Polycarbonate)+PPT Material / Black Gray

    Protection level

    IP20

 

Environmental conditions:

    Ambient temperature

   -20~60℃

    Ambient temperature (storage or operation)

   -40~80℃

    Ambient humidity (operation)

    5~95RH  (no condensation)

 

Input (intrinsically safe):

   Input Current

   4~20mA ; 0~20mA

   Input resistance

   25Ω

   Distribution voltage supplied to the transmitter

    ≥16V (at 20mA)

 

Output:

   Current output

    4~20mA ; 0~20mA

   Transmission characteristics

    1 to 1 corresponds to the input signal

   Current Output Load

    Adaptive Load 0~300Ω (factory default)

   Output ripple

    <10mV p-p

   Output status when input overload or open circuit fault

    · Input overload: Output current ≥22mA
    · Input open circuit: output current 2mA

 

Power supply:

   Rated supply voltage

   24VDC

   Power supply voltage range

   20~32VDC

   Maximum current consumption <50mA

   50mA11出);<70mA12出);
   100mA (2 in 2 out, power distribution input barrier);
   50mA (2 in 2 out, current input barrier)

 

General parameters:

  Standard accuracy

    Typical value±0.1%FS

   Temperature drift

    <±1μA/10℃

   Power-on or storage time drift

    ±2μA (180days)

   Load change effect

    ±2μA

   Response time

    <10ms

   Power-on stabilization time

    <1s

   Electrical isolation:

Input-output-power supply

    Input-output-power supply: 2500V AC RMS / 1 minute

    Protection parameters

   · Power-on shock protection, power-on slow start >20ms   

   · Distribution protection, distribution output clamp current 28mA (±4mA)
   · Reverse power supply protection, reverse voltage -30V
   · Output protection, output clamp current 22mA (typical)
   · Port misconnection and surge protection:
   A.The power-input-output between the two ports of the self-loop can withstand the external loop voltage <±24V.       

   B. Input-output-power supply can withstand 2500V RMS/1 minute without damage.       

   C. The short circuit or open circuit formed by the misconnection of the terminal is not damaged.

   Electromagnetic compatibility (EMC)

   in accordance with IEC 61326-1 (GB/T 18268), IEC 61326-3-1

   LED backlight indication

   Power on, the product model on the panel is clearly visible through the LED backlight perspective, white.

   Applicable occasions

   Installed in a safe place, can be connected with intrinsically safe equipment in Zone 0, Zone 1, Zone 2; IIC, IIB, IIA; T4~T6 danger zone

    Field device suitable for connection

   Transmitter or current source signal

   Mounting method

   Horizontal or vertical mounting, can be mounted on standard 35mm DIN rail (or dedicated busbar backplane powered DIN rail)

 

Wiring parameters:

   Rigid conductor cross section (min/max)

   0.5mm²/2.5mm²

   Flexible conductor cross section (min/max)

   0.5mm²/2.5mm²

   Minimum Conductor Cross Section (AWG))

   24

   Maximum Conductor Cross Section (AWG) 14

   14

   Stripping length

   7mm

   Connection type

   M3 screw fastening connection

   Screw torque

   Up to0.6Nm

 

Explosion-proof parameters:

   Name

    Distributor operation (terminal 1-2)

    Isolator operation (terminals 2-3)

   Maximum output voltage (Uo)

    26.2VDC

    7.2VDC

   Maximum output current (Io)

    127mA

    3.7mA

   Maximum output power (Po)

    0.83W

    7mW

   Maximum external inductance (Lo)

    1.5mH

    2.4mH

   Maximum external capacitance (Co)

    0.05μF

    4μF

   Maximum safety voltage (Um)

    250VDC/AC

 

Certification/Standards:

   CE certification

    in line with CE standards

   National Explosion-proof Electrical Product Quality Supervision and Inspection Center (CQST) certification

    [Ex ia Ga] IIC conforms to GB 3836.1, GB 3836.4, GB 3836.20

Product drawing / terminal wiring diagram:

           

Product Image Details

XSA-PI /PD/ II power distribution or current input barrier 1

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

Only registered users can write reviews. Please Log In or Register

Product Questions

  • Submit your question to our community.


Our customers love us

  • High Quality With Global Standards.
  • Convenient and friendly customer service.
  • Fast and safe shipping around the globe.
  • Free Shipping Worldwide - Each Order, and no any tax!